Professional supplier of radiation detection

18 Years Manufacturing Experience
banner

RJ11-2100 Vehicle Radiation Portal Monitor (RPM)

Short Description:

High-sensitivity Plastic Scintillator

Local and Remote Light and Audible Alarm

Autamated Alert and Logging Software

Ingress Protection lP65

Optional Radionuclide ldentification and Neutron Detector

Customization Available upon Request


Product Detail

Product Tags

Product Profile

The RJ11-2100 Vehicle Radiation Portal Monitor (RPM) is primarily used to monitor if there are radioactive materials carried by trucks, container vehicles, trains, and if other vehicles contain excessive radioactive substances. The RJ11 Vehicle RPM is equipped with plastic scintillators by default, with sodium iodide (NaI) and ³He gas proportional counter as optional components. It features high sensitivity, low detection limits, and rapid response, enabling real-time automatic monitoring of various passageways. Combined with auxiliary functions such as vehicle speed detection, video surveillance, license plate recognition, and container number identification (optional), it effectively prevents the illegal transportation and spread of radioactive materials. It is widely used for radioactive monitoring and control at exits and entrances of nuclear power plants,customs,airports, railway stations, etc. The monitoring system complies with the relevant requirements of the Chinese standard GB/T 24246-2009 "Radioactive and Special Nuclear Material Monitoring Systems". The optional radionuclide identification module complies with the relevant requirements of the Chinese standard GB/T 31836-2015 "Spectrometry-Based Portal Monitors Used for the Detection and Identification of Illicit Trafficking of Radioactive Material".

System Model

Model
Features

Detector
Type
Detector
Volume

Equipment
Net Height

Recommended Monitoring
Height Range

Recommended Monitoring
Width Range

Permissible Vehicle
Speed Range

RJ11-2100

Plastic Scintillator

100 L

4.3 m

(0.1~5) m

5.0 m

(0~20)km/h

Applications

Healthcare, Recycling Resources, Metallurgy, Steel, Nuclear Facilities, Homeland Security, Customs Ports, Scientific Researchs/Laboratories, Hazardous Waste Industry, etc.

System Composition

Standard Essential System Hardware Components:
(1)y Detection Module: Plastic scintillator + low-noise photomultiplier tube
➢ Support Structure: Upright columns and waterproof enclosures
➢ Detector Collimation: Lead shielding box with 5-sided lead surrounding
➢ Alarm annunciator: Local and remote audible & visual alarmsystems, 1 set each
➢ Central Management and Control System: Computer, hard disk,database, and analysis software, 1 set
➢ Transmission Module: TCP/lP transmission components, 1 set
➢ Occupancy and Passage Speed Sensor: Through-beam infrared speedmeasurement system
➢ License Plate Recognition: High-definition night vision continuous video& photo capture device, 1 set each

Technical Characteristics

1. BlN (Background ldentification of Normal) Background Neglect Technology
This technology enables high-speed detection of lowlevel artifcial radioacive materials even in high radiation background environments, with a detectiontime as fast as 200 milisecond. lt alows for the detection of radioactive materials while vehicles are moving at high speeds, making it suitable for rapidinspection. Simultaneously, it ensures the device does not generate false alarms due to signifcant increases inbackground radiation. Furthermore, itcompensates for the reduchion in background count rate caused bythe shielding of natural radiation when a vehicle occupies the detection zone, enhancingthe authenticity of inspection results and improving the probabilty of detecton. This is paricularly beneicialfor detecting weak radioactive sources.

2. NORM Rejection Function
This function is used to identify and distinguish Naturally Occurring Radicacive Materials (NORM) lt assists operators in determining whether an alarm istriggered by artificial or natural radioactive substances.

3. Characteristic SlGMA Statistical Algorithm
Using the characteristic SIGMA alkorithm, users can easily adjust the relatonship between the device's detecton sensitivity and the probabiity of false alarmsIt allows for increasing sensitivity to detect extremely weak radioachve sources (e.g., lost sources) in specific scenarios, or prevening false alarms duringlong-term continuous monitoring, providing precise control.

Fsoftware Interface

Monitoring Sofiware Main Interface

System Installation Diagram

System Installation Diagram

Certificate

IEC 61326-2021_01
IEC 62244  2019_01
IEC 62244  2019_02
IEC 62244  2019_03
IEC 62244  2019_04
IEC 62244  2019_05
IEC 62244  2019_06

FAQ

1. For radionuclide identificiation if we already bought the RPM, in the future if we also need radionuclide identification we can just also installed it into our existing RPM right?

As for adding identification in existing RPM, in theory, yes, but in paractice, i would not suggerst doing so, because the module is not light, if RPM lies on the ground then adding detectors and analyzers and doing addtional wiring job are simple, but for already installed RPM, it's very not easy to do, especially for the larger model 2100.

2. Regarding sensor maintenance, can it be cleaned? If so, what is the cleaning method? I am concerned that dust might cover it and affect the readings.

Our sensors do not require cleaning. It is sealed. In fact, the outside can be cleaned simply by letting it rain.

3. The CCTV storage how long it can save the data on it 1 weeks or 1 month?

Generally speaking, it's about 10 years. It's based on the computer's memory. Our computer has 1 terabyte of memory. Please note that this is not a video recording, but rather a record based on photo captures.

4. I want to ask if we need an engineer from you, but our warranty already expired, how much is the cost to call your engineer.

You will be responsible for the cost of round-trip air tickets and accommodation. And you will pay 150 US dollars per day. It usually takes about 5 working days.

5. What ISO that ER-GODI is complied? What is RPM of ergoDI compliant with the standard you mention?

ISO 9001-2015, IEC 62244 : 2019 and IEC 61326-2021.

6. All for RJ11-2100, need how many Watts and voltage?

AC 220V, 50Hz, 100W (excluding PC).

7. All the RPM complete with 100m cable, isn't it?

100 meters are for power supply and communication.Theoretically, we can also use the local computer of RPM. To enable further transmission. If the customer has this requirement. But usually, 100 meters is sufficient for a steel factory.