OEM Customized Personal Digital Dosimeters - RJ12 series channel type pedestrian, line package radiation monitoring equipment – Ergodi Detail:
① The BIN (Background Identification of Normal) background ignores the technology
② MCA multispectrum analyzer, characteristic SIGMA statistical algorithm
③ NORM function (40K) Quick distinguish between common artificial and natural nuclides (e. g40K、232Th)
④ Nuclide recognition function (with sodium iodide probe / optional)
⑤ Combining the sodium iodide detector and the MCA multichannel energy spectrometer analyzer can accurately distinguish between medical nuclides, industrial nuclides, and natural radionuclides
| Natural nuclide | 40K、226Ra、232Th |
| Industrial nuclide | 241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y |
| Medical nuclides | 131I、201Tl、203Hg、18F、99mTc、99Mo、192Ir |
| Special nuclear materials | 57Co、152Eu、238U |
⑥ High-speed sampling (fastest: 200ms)
| project name | Parameter information |
| Types of detectors | American EJ original imported plate plastic scintillator + Japan Hamamatsu low noise photomultiplier tube |
| Detector volume | 5,10,15 optional with dual probe (door default dual probe) |
| Maximum pass rate | 106cps |
| energy range | 25keV~3MeV |
| sensitivity | m5000cps / (Sv / h) (10 L, relative137Cs) |
| Detection lower limit | Ability to detect radiation above the background of 5nSv / h |
| Optional one, the neutron tube |
|
| Optional dinnuclide recognition |
|
Misalarm rate
In a stable environment:
Use the space sensor, 10000 times, false alarm rate 1
Without using the occupying sensor, the false alarm rate and misidentification rate are used once within 12h
γ Radiation Response
Occupup 50 times, alarm 49 times
outrange
Over 100 v S / h, a high radiation alarm is emitted and removed within 1min after the source leaves
Radiation-induced neutron alarm
No neutron alarm is triggered when the dose rate reaches 100 Sv / h
Background influence
When the background change is large enough to cause a large change in the alarm probability, the monitoring system shall issue a warning prompt
Nuclide recognition
| Natural nuclide | 40K、226Ra、232Th |
| Industrial nuclide | 241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y |
| Medical nuclides | 131I、201Tl、203Hg、18F、99mTc、99Mo、192Ir |
| Special nuclear materials | 57Co、152Eu、238U |
Note: Nuclide identification and neutron detection are optional, not in the standard system
Product detail pictures:


Related Product Guide:
By using a full scientific excellent administration method, great quality and fantastic religion, we get good reputation and occupied this discipline for OEM Customized Personal Digital Dosimeters - RJ12 series channel type pedestrian, line package radiation monitoring equipment – Ergodi, The product will supply to all over the world, such as: Roman, Sri Lanka, Italy, Our next goal is to exceed the expectations of every client by offering outstanding customer service, increased flexibility and greater value. All in all, without our customers we do not exist; without happy and fully satisfied customers, we fail. We are looking for the wholesale, Drop ship. Please contact us if you are interesting our products. Hope to do business with you all. High quality and fast shipment!
The company's products very well, we have purchased and cooperated many times, fair price and assured quality, in short, this is a trustworthy company!
-
High definition Dosimeter Alarm - RJ31-1155 Pe...
-
Factory source X Ray Thyroid Shield - RJ32-210...
-
Ordinary Discount Radiation Protection System -...
-
OEM/ODM Supplier Dosimeter Radiation Detector -...
-
Chinese Professional Scintillation Counter - ...
-
Special Design for Nuclear Radiation Shielding ...