Lowest Price for Digital Radiation Survey Meter - RJ12 series channel type pedestrian, line package radiation monitoring equipment – Ergodi Detail:
① The BIN (Background Identification of Normal) background ignores the technology
② MCA multispectrum analyzer, characteristic SIGMA statistical algorithm
③ NORM function (40K) Quick distinguish between common artificial and natural nuclides (e. g40K、232Th)
④ Nuclide recognition function (with sodium iodide probe / optional)
⑤ Combining the sodium iodide detector and the MCA multichannel energy spectrometer analyzer can accurately distinguish between medical nuclides, industrial nuclides, and natural radionuclides
| Natural nuclide | 40K、226Ra、232Th |
| Industrial nuclide | 241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y |
| Medical nuclides | 131I、201Tl、203Hg、18F、99mTc、99Mo、192Ir |
| Special nuclear materials | 57Co、152Eu、238U |
⑥ High-speed sampling (fastest: 200ms)
| project name | Parameter information |
| Types of detectors | American EJ original imported plate plastic scintillator + Japan Hamamatsu low noise photomultiplier tube |
| Detector volume | 5,10,15 optional with dual probe (door default dual probe) |
| Maximum pass rate | 106cps |
| energy range | 25keV~3MeV |
| sensitivity | m5000cps / (Sv / h) (10 L, relative137Cs) |
| Detection lower limit | Ability to detect radiation above the background of 5nSv / h |
| Optional one, the neutron tube |
|
| Optional dinnuclide recognition |
|
Misalarm rate
In a stable environment:
Use the space sensor, 10000 times, false alarm rate 1
Without using the occupying sensor, the false alarm rate and misidentification rate are used once within 12h
γ Radiation Response
Occupup 50 times, alarm 49 times
outrange
Over 100 v S / h, a high radiation alarm is emitted and removed within 1min after the source leaves
Radiation-induced neutron alarm
No neutron alarm is triggered when the dose rate reaches 100 Sv / h
Background influence
When the background change is large enough to cause a large change in the alarm probability, the monitoring system shall issue a warning prompt
Nuclide recognition
| Natural nuclide | 40K、226Ra、232Th |
| Industrial nuclide | 241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y |
| Medical nuclides | 131I、201Tl、203Hg、18F、99mTc、99Mo、192Ir |
| Special nuclear materials | 57Co、152Eu、238U |
Note: Nuclide identification and neutron detection are optional, not in the standard system
Product detail pictures:


Related Product Guide:
With our superb management, potent technical capability and strict quality command procedure, we go on to provide our shoppers with trustworthy high-quality, reasonable costs and outstanding services. We goal at becoming considered one of your trustworthy partners and earning your pleasure for Lowest Price for Digital Radiation Survey Meter - RJ12 series channel type pedestrian, line package radiation monitoring equipment – Ergodi, The product will supply to all over the world, such as: Slovakia, kazan, Russia, Our mission is to deliver consistently superior value to our customers and their clients. This commitment permeates everything we do, driving us to continuously develop and improve our products and the processes to fulfill your needs.
This manufacturers not only respected our choice and requirements, but also gave us a lot of good suggestions, ultimately, we successfully completed the procurement tasks.
-
Cheap PriceList for Handheld Radiation Monitor ...
-
Factory selling Radiation Safety Time Distance ...
-
New Delivery for Alpha Scintillation Detector -...
-
2022 wholesale price Channel Radioactivity - ...
-
Cheapest Price Radiation Safety Equipment - RJ...
-
OEM/ODM Manufacturer Lead Shielding For Radiati...