Good Wholesale Vendors Alpha Radiation Survey Meter - RJ12 series channel type pedestrian, line package radiation monitoring equipment – Ergodi Detail:
① The BIN (Background Identification of Normal) background ignores the technology
② MCA multispectrum analyzer, characteristic SIGMA statistical algorithm
③ NORM function (40K) Quick distinguish between common artificial and natural nuclides (e. g40K、232Th)
④ Nuclide recognition function (with sodium iodide probe / optional)
⑤ Combining the sodium iodide detector and the MCA multichannel energy spectrometer analyzer can accurately distinguish between medical nuclides, industrial nuclides, and natural radionuclides
| Natural nuclide | 40K、226Ra、232Th |
| Industrial nuclide | 241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y |
| Medical nuclides | 131I、201Tl、203Hg、18F、99mTc、99Mo、192Ir |
| Special nuclear materials | 57Co、152Eu、238U |
⑥ High-speed sampling (fastest: 200ms)
| project name | Parameter information |
| Types of detectors | American EJ original imported plate plastic scintillator + Japan Hamamatsu low noise photomultiplier tube |
| Detector volume | 5,10,15 optional with dual probe (door default dual probe) |
| Maximum pass rate | 106cps |
| energy range | 25keV~3MeV |
| sensitivity | m5000cps / (Sv / h) (10 L, relative137Cs) |
| Detection lower limit | Ability to detect radiation above the background of 5nSv / h |
| Optional one, the neutron tube |
|
| Optional dinnuclide recognition |
|
Misalarm rate
In a stable environment:
Use the space sensor, 10000 times, false alarm rate 1
Without using the occupying sensor, the false alarm rate and misidentification rate are used once within 12h
γ Radiation Response
Occupup 50 times, alarm 49 times
outrange
Over 100 v S / h, a high radiation alarm is emitted and removed within 1min after the source leaves
Radiation-induced neutron alarm
No neutron alarm is triggered when the dose rate reaches 100 Sv / h
Background influence
When the background change is large enough to cause a large change in the alarm probability, the monitoring system shall issue a warning prompt
Nuclide recognition
| Natural nuclide | 40K、226Ra、232Th |
| Industrial nuclide | 241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y |
| Medical nuclides | 131I、201Tl、203Hg、18F、99mTc、99Mo、192Ir |
| Special nuclear materials | 57Co、152Eu、238U |
Note: Nuclide identification and neutron detection are optional, not in the standard system
Product detail pictures:


Related Product Guide:
Like a result of ours specialty and repair consciousness, our enterprise has won a superb popularity amid buyers everywhere in the environment for Good Wholesale Vendors Alpha Radiation Survey Meter - RJ12 series channel type pedestrian, line package radiation monitoring equipment – Ergodi, The product will supply to all over the world, such as: Holland, Philadelphia, Surabaya, Our staffs are adhering to the Integrity-based and Interactive Development spirit, and the tenet of high quality Quality with Excellent Service. According to the needs of every customer, we give customized & personalised services to help customers achieve their goals successfully. Welcome clients from home and abroad to call and inquire!
This company has the idea of better quality, lower processing costs, prices are more reasonable, so they have competitive product quality and price, that's the main reason we chose to cooperate.
-
Chinese wholesale Gm Counter And Scintillation ...
-
Popular Design for Block Gamma Radiation - RJ3...
-
One of Hottest for Radiation Protection In Medi...
-
Best quality Measurement Of Radioactivity By -...
-
China OEM Nuclear Radiation Suit - RJ33 multi-...
-
High Quality Radiation And Protection - RJ38-3...