Factory Cheap Hot X Ray Detector - RJ12 series channel type pedestrian, line package radiation monitoring equipment – Ergodi Detail:
① The BIN (Background Identification of Normal) background ignores the technology
② MCA multispectrum analyzer, characteristic SIGMA statistical algorithm
③ NORM function (40K) Quick distinguish between common artificial and natural nuclides (e. g40K、232Th)
④ Nuclide recognition function (with sodium iodide probe / optional)
⑤ Combining the sodium iodide detector and the MCA multichannel energy spectrometer analyzer can accurately distinguish between medical nuclides, industrial nuclides, and natural radionuclides
| Natural nuclide | 40K、226Ra、232Th |
| Industrial nuclide | 241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y |
| Medical nuclides | 131I、201Tl、203Hg、18F、99mTc、99Mo、192Ir |
| Special nuclear materials | 57Co、152Eu、238U |
⑥ High-speed sampling (fastest: 200ms)
| project name | Parameter information |
| Types of detectors | American EJ original imported plate plastic scintillator + Japan Hamamatsu low noise photomultiplier tube |
| Detector volume | 5,10,15 optional with dual probe (door default dual probe) |
| Maximum pass rate | 106cps |
| energy range | 25keV~3MeV |
| sensitivity | m5000cps / (Sv / h) (10 L, relative137Cs) |
| Detection lower limit | Ability to detect radiation above the background of 5nSv / h |
| Optional one, the neutron tube |
|
| Optional dinnuclide recognition |
|
Misalarm rate
In a stable environment:
Use the space sensor, 10000 times, false alarm rate 1
Without using the occupying sensor, the false alarm rate and misidentification rate are used once within 12h
γ Radiation Response
Occupup 50 times, alarm 49 times
outrange
Over 100 v S / h, a high radiation alarm is emitted and removed within 1min after the source leaves
Radiation-induced neutron alarm
No neutron alarm is triggered when the dose rate reaches 100 Sv / h
Background influence
When the background change is large enough to cause a large change in the alarm probability, the monitoring system shall issue a warning prompt
Nuclide recognition
| Natural nuclide | 40K、226Ra、232Th |
| Industrial nuclide | 241Am、137Cs、60Co、57Co、22Na、133Ba、54Mn、88Y |
| Medical nuclides | 131I、201Tl、203Hg、18F、99mTc、99Mo、192Ir |
| Special nuclear materials | 57Co、152Eu、238U |
Note: Nuclide identification and neutron detection are optional, not in the standard system
Product detail pictures:


Related Product Guide:
Our company since its inception, constantly regards product or service high quality as business life, continually improve creation technology, make improvements to product high-quality and consistently strengthen business total high-quality management, in strict accordance together with the national standard ISO 9001:2000 for Factory Cheap Hot X Ray Detector - RJ12 series channel type pedestrian, line package radiation monitoring equipment – Ergodi, The product will supply to all over the world, such as: Latvia, Japan, Tajikistan, If you have any requests, pls email Us with your detailed demands, we will give you wholesale Competitive Price with the Super Quality and the Unbeatable high quality Service ! We can give you competitive prices and high quality, because we are much more PROFESSIONAL! So please do not hesitate to contact us.
This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
-